Executive Summary
For the 1981 model year, EPA first tied the FTP-75 to a 2-gram SHED evaporative emission limit. This laid the foundation for all future evaporative rulemakings: the assumption that the engine will run long enough during the Federal Test Procedure (FTP-75) dynamometer test run (canister purge drive) to sufficiently purge the carbon canister to meet the emission limits of the combined hot soak and 48-hour diurnal and eventually the bleed emission standard. Since the 1981 model year, full vehicle evaporative limits have been cut 85% for LDVs and canister bleed emission limits have been pushed to near-zero. Over the last 10-20 years, powertrain technology to improve fuel economy has rapidly advanced and is becoming much more commonly applied. Technologies, such as engine start-stop and full hybridization, are significantly reducing engine run-time over the FTP-75 and consequently limiting the opportunity to purge the canister.
For conventional internal combustion engine vehicles (ICEV), the engine operates for the full 31.2 minutes of the FTP-75 and the canister is purged for 20 to 25 minutes. On a modern hybrid electric vehicle (HEV), however, the engine runs for only roughly 11 to 13 minutes, and purge occurs for only about 7 to 8 minutes — a reduction of approximately 70 percent in purge-on time relative to ICEV variants of the same model. With so little engine operation, the opportunity to generate sufficient purge on HEVs to meet the near-zero evaporative standard using conventional fuel tanks is increasingly squeezed.
For HEVs, manufacturers are responding by increasingly abandoning the integrated canister systems and adopting sealed fuel tanks with non-integrated refueling canister-only systems (NIRCOS). A NIRCOS design is exempt from the canister bleed emission test procedure (BETP), allowing purge to be calibrated against the 97 minutes of drive time available in the onboard refueling vapor recovery (ORVR) test sequence. This is not a neutral substitution. Sealed tanks add roughly $100 to $200 per vehicle in cost, and in-use verification program (IUVP) data show they perform worse than conventional fuel tank vehicles. EPA’s IUVP database, for model years 2017 and later, shows vehicles with sealed tanks fail the 48-hour diurnal test 40 percent more often than vehicles with conventional tanks (13.3% vs. 9.5%), and, when they do fail, the exceedance is more than three times larger (7.79 × standard vs. 2.39 × standard). Most significantly, the average ratio of IUVP measured result to the certifying standard is 1.48 for sealed-tank families and 0.71 for conventional- tank families. On a fleet basis, in-use diurnal emissions from sealed-tank vehicles are approximately double those of conventional-tank vehicles. Very small diameter leaks in sealed tanks lead to very high emissions, and the higher in-use emissions for vehicles with sealed tanks are likely attributable to leaks. The 97% average IUVP ORVR pass rate over nine model years leads us to this conclusion.
The inability to generate sufficient purge during the FTP dynamometer test run prior to evaporative emissions certification testing can be remedied through a certification test procedure flexibility for HEVs. This flexibility would not change any exhaust or evaporative emission standard, or how exhaust emissions are measured; it would change only the drive time available to purge the canister. The flexibility will enable automakers to both reduce costs related to sealed tanks and ensure that in-use evaporative emissions are controlled by avoiding vapor leaks in use from vehicles with sealed tank designs. The simplest way to provide this flexibility could come in the form of extended canister pre-conditioning drive time (dynamometer test run) for the 48-hour diurnal test and the BETP. This action has precedence for heavy duty gasoline vehicles with fuel tanks at or above 50 gallons, which faced a similar situation of not being able to generate sufficient purge volume over a single FTP-75, and were afforded additional preconditioning drive time to help address this issue.
Dive deeper into the full report.